<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-26 16-49-49
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 56 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.8 kHz -8 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 71 kHz 10080 0,0298
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,6 dBr 7,43 dBr 8,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 16:49, 26.07.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (56 dBuV) Max at: 71 kHz MIN: 11 kHz % above 75 kHz: 0,0298 Acquired: 2025/07/26 16:48:45 Total samples: 10080 Equivalent time: 0:08:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,0 dBr MIN: 6,6 dBr AVE: 7,43 dBr % above 10,2 dBr: 0,0 Last value: 7,7 dBr (2025/07/26 16:48:45) Station: 96.90 MHz, signal: 5/5 (56 dBuV) 16:42 16:43 16:44 16:45 16:46 16:47 16:48 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality